Application:
Spray Nozzle Protection/Industry Classification: White Water
Background:
A
manufacturer of recycled paper installed an automatic type
filter to protect a row of spray nozzles. The filter was
unable to sufficiently clean itself, causing a loss of flow
to the nozzles. These nozzles control the amount of moisture
added to the rolled paper during the process. Insufficient
moisture causes paper breaks.
Solution:
Due to the low flow rate of the system and the relatively
high temperature of the water, a three pod EasyClean filter
unit was installed. All stainless steel filter elements
were used due to the high temperature requirement. The system
is configured so that in filter mode, all three filter elements
are on-line. During backwash each pod is cleaned sequentially
by using an external clean water supply.
Application
Details:
Filter
Specifications:
Flow Rate: 15 gpm, Filter: Three pod Easyclean
Micron Rating: 50 micron, Filter Elements: Stainless steel
cages
Temperature: 190ºF, Backwash Source: External
Results:
Since installation of filter, spray nozzles have remained
clear and manufacturer has noticed significantly fewer paper
breaks. Filter has consistently returned to its clean differential
pressure upon completion of each backwash with no downtime
or maintenance.
Date:
December 7, 2000
Download
Sucess Story PDF 
Return